VAV
Terminal Units |
|
Series
Flow (Constant Volume) Fan Powered Terminal Units |
| |
|
|
|
| |
|
|
Series
Flow (Constant Volume) Fan Powered Terminal Units
35S
Series • Quiet constant fan operation.
• Available in 6 fan sizes, each with various primary
air inlet size options for optimum design flexibility.
300 – 3700 cfm (140 – 1746 l/s) flow range.
• High performance inclined opposed blade primary air
damper.
|
|
• 'Diamond
Flow' multi-point averaging sensor.
• Custom high efficiency PSC motor/blower design.
• Solid state fan speed controller.
• Pressure independent airflow control.
• Pneumatic, analog electronic or digital control.
• Available 'Q' option induced air attenuator.
• Options include hot water coils or integral electric coils for supplementary
heat.
• Various 'IAQ' linings.
• Available with ultra-high efficiency EPICTM/ECM motor technology. |
|
|
 |
Super
Quiet "Stealth™" Series Flow
(Constant Volume) Fan Powered Terminal Units
35SST "Stealth™" Series
• Super
quiet premium design. Constant fan operation.
• "Stealth™" design technology.
|
• Available
in 6 fan sizes, each with various primary air inlet size options
for optimum design flexibility. 300 – 3700 cfm (140 – 1746
l/s) flow range.
• High performance inclined opposed blade primary air damper.
• 'Diamond Flow' multi-point averaging sensor.
• Custom high efficiency PSC motor/blower design.
• Solid state fan speed controller.
• Pressure independent airflow control.
• Pneumatic, analog electronic or digital control.
• Options include hot water coils or integral electric coils for supplementary
heat.
• Various 'IAQ' linings.
• Available with ultra-high efficiency PICTM/ECM motor technology. |
|
|
Low
Profile Series Flow Fan Powered Terminal Units
37S
Series
• Only
11" (279) in height.
• Designed especially for applications where ceiling plenum space is restricted.
|
 |
• Quiet
constant fan operation.
• Available in 4 fan sizes, each with various primary air inlet size options
for design flexibility. 300 – 2000 cfm (140 – 940 l/s) flow range.
• High performance inclined opposed blade primary air damper.
• 'Diamond Flow' multi-point averaging sensor.
• Custom high efficiency PSC motor/blower design.
• Solid state fan speed controller.
• Pressure independent airflow control.
• Pneumatic, analog electronic or digital control.
• Available 'Q' option induced air attenuator.
• Options include hot water coils or integral electric coils for supplementary
heat.
• Various 'IAQ' linings.
• Available with ultra-high efficiency PICTM/ECM motor technology. |
|
|
 |
Low
Profile Series Flow Fan Powered Terminal Units
37SST "Stealth™" Series
Incorporates
all of the features and benefits found in the 37S standard low
profile terminal unit plus the following: |
• Super
quiet premium design.
• "Stealth™" design
technology.
• Available with ultra-high efficiency PICTM/ECM motor technology. |
|
|
Series
Flow (Constant Volume) Fan Powered Terminal Units With Outside
Air Inlets
35STL
Series
35STLST "Stealth™" Series
Incorporates
the features and benefits found in the standard fan powered terminal
unit design with a dual duct inlet configuration.
|
 |
• Separate
outside air ventilation inlet damper is provided in addition to the
main primary air valve. This second valve is configured for constant
volume operation and helps ensure that minimum outside air ventilation
requirements are maintained at all times independent of the main
AHU operation.
• Available with ultra-high efficiency PICTM/ECM motor technology. |
|
|
 |
"Pressurization" Fan
Powered Terminal Units
35SVM
Series
• Designed
especially for critical environments such as hospital isolation
rooms and bio-tech applications.
|
• Utilizes
Nailor’s EPICTM/ECM fan motor technology with an ultra-high
efficiency 'brushless dc' motor to provide a pressure independent
assembly.
• Maintains precise volume control and compensates for changes in external
static pressure as encountered across a HEPA filter.
• Up to 1650 cfm (780 l/s) at 1" w.g. (250 Pa). |
|
|
Parallel
Flow (Variable Volume) Compact Design Fan Powered Terminal
Units
35N
Series
• Intermittent
fan operation.
• Pressure independent or dependent airflow control. |
 |
• Available
in 4 fan sizes, each with various primary air inlet size options
for optimum design flexibility. 200-2150 cfm (95 - 1015 l/s) flow
range.
• Primary air range from 0 to 4050 cfm (0 - 1912 l/s).
• Round low leakage
primary air damper.
• 'Diamond Flow' sensor.
• Access panels on underside of terminal for ease of maintenance and service.
• Energy efficient PSC fan motor with thermal overload protection.
• Adjustable solid state fan speed controller with minimum voltage stop.
• Gasketed backdraft damper mounted on fan discharge prevents primary air
from escaping through the fan section into the ceiling plenum.
• Hinged door on fan controls enclosure. |
|
|
 |
Parallel
Flow (Variable Volume) Premium Design Fan Powered Terminal Units
35P Series
• Quiet
intermittent fan operation. |
• Pressure
dependent or independent airflow
control.
• Available
in 6 fan sizes, each with various primary air inlet size
options for optimum design flexibility. 150 2250 cfm (70-1064
l/s) flow range.
• Primary
air cfm range from 0 to 4050 cfm (0 1912 l/s).
• High
performance inclined opposed blade primary air damper.
• 'Diamond
Flow' multi-point averaging sensor on pressure independent
models.
• Custom
high efficiency motor/blower design.
• Solid
state fan speed controller.
• Pneumatic,
electric, analog electronic or digital control.
• Options
include hot water coils or integral electric coils for supplementary
heat
• Various
'IAQ' linings. |
|
|