Single Duct Terminal Units - Model Series 3000 and 3100

Model Series 3000 - Designed for cooling only, cooling with reheat, heating only or heat/cool changeover applications.
• Available in 11 sizes. 0 – 6435 cfm (0 – 3037 l/s).
• Unit sizes 4 through 10 (Round inlet collars), 10 through 16 (Oval inlet collars) and 24x16 (Rectangular inlet collar) – up to 6040 cfm (2950 l/s), area maximum overall height of only 18" (457). The low profile design is advantageous where ceiling space is restricted.
• High performance inclined opposed blade damper.
• 'Diamond Flow' multi-point averaging sensor on pressure independent models.
• Pressure dependent or independent airflow control.
• Pneumatic, electric, analog electronic or digital control.
• Options include attenuators, hot water coils or integral electric coils for reheat, and various 'IAQ' linings.

Models: 3001 Cooling or Heating only, 30RW Cooling w/Hot Water Reheat (as showed), 30RE Cooling w/ Electric Heat


Model Series 3100 - Designed for cooling only, cooling with reheat, heating only or heat/cool changeover applications.
• Available in 11 sizes. 0 – 6435 cfm (0 – 3037 l/s).
• Unit sizes 4 through 10 (Round inlet collars), 10 through 16 (Oval inlet collars) and 24x16 (Rectangular inlet collar) – up to 6040 cfm (2950 l/s), area maximum overall height of only 18" (457). The low profile design is advantageous where ceiling space is restricted.
• High performance inclined opposed blade damper.
• 'Diamond Flow' multi-point averaging sensor on pressure independent models.
• Pressure dependent or independent airflow control.
• Pneumatic, electric, analog electronic or digital control.
• Options include attenuators, hot water coils or integral electric coils for reheat, and various 'IAQ' linings.

Models: 3101 Cooling or Heating only (as showed), 31RW Cooling w/ Hot Water Reheat, 31RE Cooling w/ Electric Heat


Dual Duct Terminal Units

• Model Series 3200 - Designed for control of hot or neutral and cold air. Variable volume with or without mixing or constant volume applications.
• Three models. 0 – 4050 cfm (0 – 1912 l/s).
• Extra low leakage opposed blade dampers control cold and hot decks.
• 'Diamond Flow' multi-point averaging sensor.
• Mixing models include integral attenuator with internal mixing baffles to minimize downstream stratification.
• Pressure independent airflow control.
• Pneumatic, analog electronic or digital control.
• Options include total air discharge sensing and various 'IAQ' linings. Model 3210
• For non-mixing applications. Model 3230
• Better than 1 in 12 mixing.
• Economical compact design.
• Integral mixing attenuator. Model 3240 "Blend Master™"
• Industry leading performance provides 1 in 30 mixing.
• Integral mixing attenuator.